Skip to content
MOTRS

MGB GT V8

1973-1976 / Coupe / United Kingdom

Common Electrical

Earth (Ground) Connection Corrosion

Symptoms

Intermittent electrical failures, dim lights on one side, instruments reading incorrectly, indicators flashing at wrong speed.

Cause

The MGB relies on the body as the earth return path. Corrosion at earth strap connections -- engine to body, body to frame, battery earth -- creates resistance in the circuit. This is the single most common cause of electrical problems on the MGB.

Fix

Clean every earth connection to bright metal, apply dielectric grease, and retighten.

Add supplementary earth straps if necessary.

Cost: $0--30.

Cost mentioned in fix
Cost: $0

Know something we don't?

Owned a MG MGB GT V8? Share your experience with this issue. What worked, what didn't, costs, tips. Help the community.

Submit an update